Al Jaffiliya Bus Station Waterproofing

Al Jaffiliya Bus Station
comprises a bus terminal and a multi-level building (Ground floor, 2 storeys,
and bus stop yard). The building spans an area of 19,000 square metres that
includes 484 square metres as an office area, and an area of 595 square metres
for waiting passengers. We have done Sub Structure Waterproofing & Wet Area
Waterproofing please check the material details given below that we have used.
Sub Structure Waterproofing: In Sub
Structure we have used Rubberized Bituminous Coating, Bituminous Primer with
Double Layer Waterproofing Membrane & Bituminous protection Board.
Wet Area Waterproofing: In all the Wet
Areas (Toilet, Bathroom & Pantry) we have use Polyurethane Liquid Coating.
Expansion Joint: Neoprene Backing Rod, Two Component
Polysulfide Sealant, Self-Adhesive Membrane, Sealant, Aluminum Cover Plate.
Injection Packer: Drilling of holes in concrete and injecting the chemical to arrest the water leakage.